NHG60M micro aperture gloss meter adopts small aperture 2*4mm, with 60° angle, manufactured according to ISO2813 and GB/T 9754. It is also compatible with the standards of ASTM D523, ASTM D2457. NHG60 conforms to JJG696 first class gloss meter working requirement, corresponding with CIE 1931(2°) under CIE C light source.
NHG60M gloss meter can test material with gloss (0-1000Gu), and universally apply to paint, ink, stoving varnish, coating, wood products; marble, granite, vitrified polished tile, pottery brick and porcelain; plastic, paper; hardware industries, etc. for gloss measurement and gloss data transmission.
NHG60M Micro Aperture Gloss Meter | |
Model | NHG60M |
Measure Angle |
60° Comply with standard ISO 2813、GB/T 9754、ASTM D 523、ASTM D 2457 |
Measuring Area (mm) | 2*4 |
Measurement Range | 0~1000GU |
Division Value | 0.1GU |
Measurement Range Repeatability Reproducibility |
0-10GU 10-100GU 100-1000GU ± 0.1GU ± 0.2GU ± 0.2%GU ± 0.2GU ± 0.5GU ± 0.5%GU |
Measurement Standard |
Conform with JJG696 first class gloss meter working requirement |
Chromaticity Corresponding |
Corresponding with CIE 1931(2°) under CIE C light source |
Errors |
±1.5 , ± 1.5% |
Measuring Time |
0.5s |
Dimension |
L*W*H : 160mm*75mm*90mm |
Weight |
350g |
Language |
Chinese/English |
Battery |
3.7V,3200mAh Li-ion Battery, >10000 times(within 8 hours) |
Viewing Screen |
TFT 3.5 inch, capacitive touch screen |
Interface |
USB/RS-232 |
Data Save |
Basic mode: 1000, Statistical Mode: 5000, Continuous mode : 5000 |
Software |
GQC6 Quality Control Software with QC report printing functions and more extended functions. |
Operation Temperature |
0~40℃(32~104°F) |
Storage Temperature |
-20~50℃(-4~122°F) |
Humidity | <85% relative humidity, no condensation |
Standard Accessories |
Power Adapter, USB cable, User Manual, CD (Including QC software), Calibration Plate |
Optional Accessories |
Miniature Printer |
Note |
The specifications are subject to change without notice. |
With 12 rigorous quality inspection processes in place, we ensure a high yield rate of up to 98% for batch processed precision parts.
FAQs About Gloss meter
SCI&SCE are two method in the color measurement. SCI means Specular Component Include,SCE means Specular Component Exclude.
Under the method of SCE, only test diffuse refection and exclude specular reflection. In that way, the test result is similar to object color was observed by human eyes.
Under the method SCI, both the diffuse refection and specular reflection will be included. In that way, the value about the color is more objective. It will not effect by the environment condition.
When we choose the instrument, those elements should be taking into consideration.
D/8°and 45°/0°are two kinds of illumination geometry with different optical geometry design. D/8°illumination geometry is more widely used for the color comparison and measurement of high-gloss materials; 45°/0°illumination geometry is mainly used in printing and packaging industries.
Opaque liquids and powders can be put into a cuvette for color measurement.
Now our testing machines have been sold to more than 80 countries, like USA, Canada, Russia,UK, Italy, Germany, European , India, Pakistan, Philippine, Singapore, Malaysia,Thailand , Vietnam, Korea,Saudi Arabia,Brazil...and so on. We sell to the global market.
a. When the colorimeter is disconnected to the PC, "Connection Timeout" will occur. At the moment, you have to check whether the USB cable is well connected the colorimeter and the PC. Then you can re-plug the USB to try out.
b. After ensuring the colorimeter is connected to the PC with USB cable, turn on the colorimeter and enter the main menu. Select "Comm" and press "Enter" key to start communication.
c. Turn off CQCS3 software, and reopen it.